Development and Prototype Testing
We can help with HV withstand testing of new equipment designs, along with measurement of Partial Discharge (PD) inception and extinction voltages.
Routine and Type Testing
Our facility can be used for PD testing newly manufactured components according to international standards in a low noise environment.
Design Consultancy and Advice
We can support your design process through detailed investigations of any weak points in the insulation system identified during PD measurements.
Test Capabilities
- Power Frequency (50 Hz) up to 100 kV (100 mA) with PD
- Power Frequency (50 Hz) up to 50 kV (30 mA) with PD
- Low noise level for PD measurements to 1 pC
- PD location measurements
- Temperature and humidity measurement
- Low-light photography
Test Standards
- IEC 60270:2000+AMD1:2015 High-voltage test techniques - Partial discharge measurements
- IEC TS 62478:2016 High voltage test techniques - Measurement of partial discharges by electromagnetic and acoustic methods